Skip to content

Continuing Education Courses

Course #19835 - 2017 NEC Chgs-Ovrcurrent Protct/Grndng-Bndng

Course Expiration: November 3, 2024
Course Type: Electrician
Core Credit Hours: 1.0
HVAC Specific: No
Energy Specific: No
NFPA-70E Specific: No
Course Name:2017 NEC Chgs-Ovrcurrent Protct/Grndng-Bndng
Course Outline & Objectives:Course Objectives: At the end of the day, you're going to be able to: Describe the new rules for arc energy reduction Explain the changes to the grounding of separately derived systems in 250.30. Describe the changes to the requirements for intersystem bonding terminations in 250.94. Describe the changes to sizing the equipment grounding conductor for conductors installed in parallel in 250.122(F) Course Outline: Introduction Article 240 Overcurrent Protection (10 minutes) o 240.6(A) Standard Overcurrent Device Ratings o 240.67 Arc Energy Reduction o 240.67(A) Documentation o 240.67(B) Reductions to Clearing Time Article 250 Grounding and Bonding (5 minutes) o 250.22 Circuits That Aren't Allowed to be Grounded o 250.30 Separately Derived Systems 250.52 (15 minutes) o 250.52 Types of Grounding Electrodes o 250.52(A)(1), Underground Metal Water Pipe o 250.52(A)2) Metal In-ground Support Structures o 250.52(A)(3) Concrete Encased Electrode o 250.52(A)(4) Ground Ring o 250.52(A)(5) Driven Rods and Driven Pipes o 250.52(A)(6) Other Listed Electrodes o 250.52(A)(7) Ground Plates o 250.52(A)(8) Other Metal Underground Systems and Structures o 250.52(B) Prohibited Electrodes 250.66 (10 minutes) o 250.66 Sizing of Grounding Electrode Conductors o 250.66(A) Grounding Electrode Conductor Sizing for Driven Pipes and Rods and Buried Plates o 250.66(B) Grounding Electrode Conductor Sizing for Concrete Encased Electrode o 250.66(C) Grounding Electrode Conductor Sizing for Ground Rings 250.94 (5 minutes) o 250.94(A) Intersystem Bonding Termination Device (IBT) o 250.94(B) Other Methods 250.102 Grounded/Neutral Conductors and Bonding Jumpers/Conductors (5 minutes) o how to size the service neutral conductor, the service grounded conductor o 250.102(C)(1) Sizing a Supply Side Bonding Jumper for single, raceways, or cables 250.122(F) Equipment Grounding Conductor for Conductors in Parallel (5 minutes) o 250.122(F)(1), Parallel Conductors in Raceways, Gutters, and Cable Trays o 250.122(F)(1)(b) Talks about Multiple Raceways with Parallel Conductors 250.187 Impedance Grounded Neutral Systems Over 1,000V (5 minutes) o 250.187, Impedance Grounded Neutral Systems over 1,000 volts Conclusion o Summary and Implications
Course Schedule N/A
Calendar Events
Keywords: 2017 NEC, Overcurrent, Protection, Grounding, Bonding
Location(s): N/A - Distance Learning Course
Teaching Method: Internet
Company Name: Vector Solutions
Phone: 866.546.1212
Address: 4890 W. Kennedy Blvd. Suite 300
City: Tampa
State: FL
Postal Code: 33609
Email Address: VSAccreditations@vectorsolutions.com
The Course Provider is: a commercial continuing education provider related to the construction trades
Signup Link: https://www.vectorsolutions.com
Instructor First Name: Ryan
Instructor Last Name: Jackson
Instructor License #:
Instructor Resume:
Instructor Resume: Jackson, Ryan.PDF
Instructor First Name: Ryan
Instructor Last Name: Jackson
Instructor License #:
Instructor Resume:
Instructor Resume: Jackson, Ryan.PDF
Instructor First Name: Ryan
Instructor Last Name: Jackson
Instructor License #:
Instructor Resume:
Instructor Resume: Jackson, Ryan.PDF
Instructor First Name: Ryan
Instructor Last Name: Jackson
Instructor License #:
Instructor Resume:
Instructor Resume: Jackson, Ryan.PDF

Back Search Courses Search Licenses