Continuing Education Courses
Course #22303 - 2017 NEC Chgs-Ovrcurrent Protct/Grndng-Bndng
Course Expiration: |
September 11, 2026 |
Course Type: |
Electrician |
Core Credit Hours: |
1.0 |
HVAC Specific: |
No |
Energy Specific: |
No |
NFPA-70E Specific: |
No |
Course Name: | 2017 NEC Chgs-Ovrcurrent Protct/Grndng-Bndng |
Course Outline & Objectives: | Course Objectives:
At the end of the day, you're going to be able to:
Describe the new rules for arc energy reduction
Explain the changes to the grounding of separately derived systems in 250.30.
Describe the changes to the requirements for intersystem bonding terminations in 250.94.
Describe the changes to sizing the equipment grounding conductor for conductors installed in parallel in 250.122(F)
Course Outline:
Introduction
Article 240 Overcurrent Protection (10 minutes)
o 240.6(A) Standard Overcurrent Device Ratings
o 240.67 Arc Energy Reduction
o 240.67(A) Documentation
o 240.67(B) Reductions to Clearing Time
Article 250 Grounding and Bonding (5 minutes)
o 250.22 Circuits That Aren't Allowed to be Grounded
o 250.30 Separately Derived Systems
250.52 (15 minutes)
o 250.52 Types of Grounding Electrodes
o 250.52(A)(1), Underground Metal Water Pipe
o 250.52(A)2) Metal In-ground Support Structures
o 250.52(A)(3) Concrete Encased Electrode
o 250.52(A)(4) Ground Ring
o 250.52(A)(5) Driven Rods and Driven Pipes
o 250.52(A)(6) Other Listed Electrodes
o 250.52(A)(7) Ground Plates
o 250.52(A)(8) Other Metal Underground Systems and Structures
o 250.52(B) Prohibited Electrodes
250.66 (10 minutes)
o 250.66 Sizing of Grounding Electrode Conductors
o 250.66(A) Grounding Electrode Conductor Sizing for Driven Pipes and Rods and Buried Plates
o 250.66(B) Grounding Electrode Conductor Sizing for Concrete Encased Electrode
o 250.66(C) Grounding Electrode Conductor Sizing for Ground Rings
250.94 (5 minutes)
o 250.94(A) Intersystem Bonding Termination Device (IBT)
o 250.94(B) Other Methods
250.102 Grounded/Neutral Conductors and Bonding Jumpers/Conductors (5 minutes)
o how to size the service neutral conductor, the service grounded conductor
o 250.102(C)(1) Sizing a Supply Side Bonding Jumper for single, raceways, or cables
250.122(F) Equipment Grounding Conductor for Conductors in Parallel (5 minutes)
o 250.122(F)(1), Parallel Conductors in Raceways, Gutters, and Cable Trays
o 250.122(F)(1)(b) Talks about Multiple Raceways with Parallel Conductors
250.187 Impedance Grounded Neutral Systems Over 1,000V (5 minutes)
o 250.187, Impedance Grounded Neutral Systems over 1,000 volts
Conclusion
o Summary and Implications
|
Course Schedule |
N/A |
Calendar Events |
Keywords: |
2017 NEC, Overcurrent, Protection, Grounding, Bonding |
Location(s): |
N/A - Distance Learning Course
|
Teaching Method: | Internet |
Company Name: | Vector Solutions |
Phone: | 866.546.1212 |
Address: | 4890 W. Kennedy Blvd. Suite 300 |
City: | Tampa |
State: | FL |
Postal Code: | 33609 |
Email Address: | VSAccreditations@vectorsolutions.com |
The Course Provider is: | a commercial continuing education provider related to the construction trades |
Signup Link: | https://www.vectorsolutions.com |
Instructor First Name: | Ryan |
Instructor Last Name: | Jackson |
Instructor License #: | |
Instructor Resume: | |
Instructor Resume: |
Jackson, Ryan.PDF |
Instructor First Name: | Ryan |
Instructor Last Name: | Jackson |
Instructor License #: | |
Instructor Resume: | |
Instructor Resume: |
Jackson, Ryan.PDF |
Instructor First Name: | Ryan |
Instructor Last Name: | Jackson |
Instructor License #: | |
Instructor Resume: | |
Instructor Resume: |
Jackson, Ryan.PDF |
Instructor First Name: | Ryan |
Instructor Last Name: | Jackson |
Instructor License #: | |
Instructor Resume: | |
Instructor Resume: |
Jackson, Ryan.PDF |
Instructor First Name: | Ryan |
Instructor Last Name: | Jackson |
Instructor License #: | |
Instructor Resume: | |
Instructor Resume: |
Jackson, Ryan.PDF |
Back
Search Courses
Search Licenses